2018 International Building Code®

Grouped product items
Qty Format Price Member Price Member Savings
premiumACCESS Subscription

$---.--
$---.--
$---.--
Soft Cover

Item #: 3000S18

$151.00
Volume Discount
Quantity Price
1-24 $151.00
25-49 $143.45
50-99 $135.90
100 and up $128.35
$113.00
Volume Discount
Quantity Price
1-24 $113.00
25-49 $107.35
50-99 $101.70
100 and up $96.05
$38.00
Loose Leaf

Item #: 3000L18

$173.00
Volume Discount
Quantity Price
1-24 $173.00
25-49 $164.35
50-99 $155.70
100 and up $147.05
$130.00
Volume Discount
Quantity Price
1-24 $130.00
25-49 $123.50
50-99 $117.00
100 and up $110.50
$43.00
Loose Leaf & PDF/Redline Download

Item #: 3000LPR18

$216.00
$162.00
$54.00
Soft Cover & PDF/Redline Download

Item #: 3000SPR18

$200.00
$150.00
$50.00
PDF/Redline Download

Item #: 8700PR18

$136.00
Volume Discount
Quantity Price
1-1 $136.00
2-2 $102.00
3-4 $95.20
5-9 $81.60
10 and up $74.80
$102.00
Volume Discount
Quantity Price
1-1 $102.00
2-2 $76.50
3-4 $71.40
5-9 $61.20
10 and up $56.10
$34.00

The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories. For the most current adoptions details go to International Code Adoptions

The 2018 IBC contains many important changes such as:

  • Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
  • New code sections have been introduced addressing medical gas systems and higher education laboratories.
  • Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
  • Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
  • The occupant load factor for business uses has been revised to one occupant per 150 square feet.
  • Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
  • The minimum lateral load that fire walls are required to resist is five pounds per square foot.
  • Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
  • Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
  • Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
  • New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
  • Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
More Information
Description: Links

Front Matter (Title Page, TOC, Preface and Forward)

Referenced Standards

Description: Extra

This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2018 IBC contains many important changes such as:

  • Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
  • New code sections have been introduced addressing medical gas systems and higher education laboratories.
  • Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
  • Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
  • The occupant load factor for business uses has been revised to one occupant per 150 square feet.
  • Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
  • The minimum lateral load that fire walls are required to resist is five pounds per square foot.
  • Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
  • Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
  • Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
  • New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
  • Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
Publisher ICC
This site has been tested and optimized for Firefox, Safari, Chrome and Internet Explorer 10+. We recommend users of early versions of Internet Explorer to update to Version 11 or later.