ASTM C1278/C1278M—07a(2011) Standard Specification for Fiber-reinforced Gypsum Panels (PDF Download)
PURCHASE THE PDF DOWNLOAD VERSION AND GET IMMEDIATE ACCESS!!! This convenient option is a searchable PDF download that requires a PDF Reader. This option is mobile friendly and compatible with all devices, including mobile tablets and smart phones. The PDF Download is licensed per individual in which the individual can place on up to four electronic devices for their personal use. Distribution of the PDF is not permitted. For a volume license the PDF is licensed to the person in which it is assigned. Use on a local area network or other network is not permitted.
ALL PDF DOWNLOAD SALES ARE FINAL.
For ICC certification examination rules related to exam reference materials review Test Site Regulations
1.1 This specification covers fiber-reinforced gypsum panels described in 1.1.1-1.1.4.
1.1.1 Interior Fiber-Reinforced Gypsum Panels
are designed to be used for walls, ceilings, or partitions and affords a suitable surface to receive decoration.
1.1.2 Water-Resistant Fiber-Reinforced Gypsum Backing Panels
are designed primarily to be used as a base for the application of ceramic or plastic tile on walls or ceilings. This product is also suitable for decoration.
1.1.3 Exterior Fiber-Reinforced Gypsum Soffit Panels
are designed for use on exterior soffits and carport ceilings that are completely protected from contact with liquid water.
1.1.4 Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels
are designed for use as sheathing on buildings.
1.1.5 Interior Fiber-Reinforced Gypsum Underlayment Panels
are designed for use as a base for application of finished flooring materials.
1.1.6 Fiber-Reinforced Gypsum Board Panels
are designed for use in roofing systems.
1.2 Specifications applicable to all fiber-reinforced gypsum panels are located in Sections 1-4 and 11-13 except as modified by applicable product sections. Specifications applicable to specific panels are located in the following sections:
| Interior Fiber-Reinforced Gypsum Panels | 5 |
| Water-Resistant Fiber-Reinforced Gypsum Backing Panels | 6 |
| Exterior Fiber-Reinforced Gypsum Soffit Panels | 7 |
| Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels | 8 |
| Interior Fiber-Reinforced Gypsum Underlayment Panels | 9 |
| Fiber-Reinforced Gypsum Roof Board Panels | 10 |
1.3 The values stated in either inch-pound units or SI (metric) are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independently of the other. Values from the two systems shall not be combined.
1.4 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard.
This standard is referenced in the 2015 International Building Code® and 2015 International Residential Code®.
| Description: | 1.1 This specification covers fiber-reinforced gypsum panels described in 1.1.1-1.1.4. 1.1.1 Interior Fiber-Reinforced Gypsum Panels are designed to be used for walls, ceilings, or partitions and affords a suitable surface to receive decoration. 1.1.2 Water-Resistant Fiber-Reinforced Gypsum Backing Panels are designed primarily to be used as a base for the application of ceramic or plastic tile on walls or ceilings. This product is also suitable for decoration. 1.1.3 Exterior Fiber-Reinforced Gypsum Soffit Panels are designed for use on exterior soffits and carport ceilings that are completely protected from contact with liquid water. 1.1.4 Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panels are designed for use as sheathing on buildings. 1.1.5 Interior Fiber-Reinforced Gypsum Underlayment Panels are designed for use as a base for application of finished flooring materials. 1.1.6 Fiber-Reinforced Gypsum Board Panels are designed for use in roofing systems. 1.2 Specifications applicable to all fiber-reinforced gypsum panels are located in Sections 1-4 and 11-13 except as modified by applicable product sections. Specifications applicable to specific panels are located in the following sections:
1.3 The values stated in either inch-pound units or SI (metric) are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independently of the other. Values from the two systems shall not be combined. 1.4 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard. This standard is referenced in the 2015 International Building Code® and 2015 International Residential Code®. |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pages | 6 | ||||||||||||
| Code Year | 2015 | ||||||||||||
| Publisher | ASTM International | ||||||||||||
| Language | English |