Applying 2024 IFC Fire Flow and Fire Hydrant Requirements: Compliance, Coordination, and Placement (Learn Live)

Price: $---.--
Member Price: $---.--
Member Savings: $---.--
Format: Online Live
Duration: 1.50
As low as $49.00
Choose an Option...
Enrollment Details

Who will be attending/completing this course?

Complete all required fields, then “Confirm Details”. You can change details if you are registering on behalf of someone else.

“Add Attendee” can be used for additional registrations.

Add 0000 if license detail is not available.

Confirm Details
Click on for more information. Upon selecting 'None', input the last four digits of the SSN into the License Number field.
Registrant Count - 0
Available Seats - Unlimited

This instructional program outlines a practical, defensible workflow for applying the 2024 International Fire Code water-supply requirements, from calculating required fire flow to sizing, counting, and locating fire hydrants. Part I addresses the Appendix B methodology, including construction-type classification, fire-flow calculation area (FFCA), Table B105.1, sprinkler-based reductions, AHJ discretion, and plan-review documentation. Part II applies those results using Section 507 and Appendix C, including the 400/600-foot hydrant distance rule, standpipe-system hydrants, inspection and clearance requirements, and Table C102.1 for hydrant number and spacing. Worked examples and schematic layouts demonstrate how each calculation supports a compliant hydrant plan.
More Information
Objectives
  • Calculate required fire flow using Appendix B by applying construction type and fire-flow calculation area (FFCA).
  • Evaluate sprinkler reductions and AHJ discretion under Sections B105.2 and B103, with documentation supporting a defensible plan-review record.
  • Interpret the 400/600-foot distance rule in Section 507.5.1, including when Exceptions 1 and 2 permit a 600-foot hose-lay distance.
  • Identify related hydrant provisions for standpipe-system hydrants, inspection and maintenance, clearance, access, and physical protection.
  • Use Appendix C and Table C102.1 to determine hydrant number and spacing, including applicable sprinkler and site-condition adjustments.
  • Develop a compliant hydrant layout by measuring true hose-lay paths and applying placement practices for single, mixed, sprinklered, and multi-building sites.