Design Guide Volume 2: City of Los Angeles Mandatory Earthquake Hazard Reduction in Existing Wood-Frame Buildings with Soft, Weak or Open-Front Walls (SWOF) (PDF Download)
PURCHASE THE PDF DOWNLOAD VERSION AND GET IMMEDIATE ACCESS!!! This convenient option is a searchable PDF download that requires a PDF Reader. This option is mobile friendly and compatible with all devices, including mobile tablets and smart phones. The PDF Download is licensed per individual in which the individual can place on up to four electronic devices for their personal use. Distribution of the PDF is not permitted. For a volume license the PDF is licensed to the person in which it is assigned. Use on a local area network or other network is not permitted.
ALL PDF DOWNLOAD SALES ARE FINAL.
For ICC certification examination rules related to exam reference materials review Test Site Regulations
This design guide provides an example and detailed commentary for the seismic strengthening of existing wood-frame buildings with soft, weak or open-front (SWOF) wall lines subject to the recently passed mandatory Los Angeles Ordinance. The design example in this guide demonstrates a prescriptive, ordinance-based retrofit approach for a typical open-front wall line. Following this example, a demonstration is given showing how FEMA P807 could be used to design a retrofit for the same example building.
Commentary in the guide discusses challenges inherent in this type of retrofit including: lateral force-resisting system selection, shear transfer detailing, and existing material capacities. Additionally, capacity-based design concepts are presented to provide creative solutions for buildings with unique challenges. Scope, responsibilities of the design professional, and other topics are discussed in great detail to further aid the design professional and provide a clearer understanding of the requirements of the Ordinance.
This design guide was written for use with the 2014 City of Los Angeles Building Code based on the 2012 International Building Code and ASCE 7-10. This guide is an excellent resource for practicing professional engineers, architects, building officials, academics, and students evaluating this type of structure.
Description: | This design guide provides an example and detailed commentary for the seismic strengthening of existing wood-frame buildings with soft, weak or open-front (SWOF) wall lines subject to the recently passed mandatory Los Angeles Ordinance. The design example in this guide demonstrates a prescriptive, ordinance-based retrofit approach for a typical open-front wall line. Following this example, a demonstration is given showing how FEMA P807 could be used to design a retrofit for the same example building. Commentary in the guide discusses challenges inherent in this type of retrofit including: lateral force-resisting system selection, shear transfer detailing, and existing material capacities. Additionally, capacity-based design concepts are presented to provide creative solutions for buildings with unique challenges. Scope, responsibilities of the design professional, and other topics are discussed in great detail to further aid the design professional and provide a clearer understanding of the requirements of the Ordinance. This design guide was written for use with the 2014 City of Los Angeles Building Code based on the 2012 International Building Code and ASCE 7-10. This guide is an excellent resource for practicing professional engineers, architects, building officials, academics, and students evaluating this type of structure. |
---|---|
Code Year | 2017 |
Publisher | ICC |
Language | English |